1st 2nd 3rd Display Function
Default,
( ): For Europe
Settings/Range Comments Report
2 917 Paper Trans Reverse Crnt
Sets the negative voltage applied
to the paper transfer corona unit.
This is applied at all times, except
during toner transfer to the paper.
1700 1000 to 2500 V
Do not change the factory
setting.
2 918 0 P.T.C.(Pre-rotation)
Sets the current for the paper
transfer corona unit, which is used
to make the residual voltage on
the transfer belt even.
100
50 to 500 (
µ
A)
2 950 1 Main Scn Mag:Copier
Adjusts the magnification of the
main scanning direction for copier
mode.
0 -2.0 to +2.0 %
Do not change the factory
setting.
2 950 2 Main Scn Mag:Printer
Adjusts the magnification of the
main scanning direction for printer
mode.
0 -2.0 to +2.0 %
Do not change the factory
setting.
3 972 1 LD Writing ON/OFF: K Selects whether the LD works or
not for each color image.
Whichever it is, the sensor pattern
for each color is made to control
the toner concentration.
- 0: No, 1: Yes
Do not change the factory
settings.
3 972 2 LD Writing ON/OFF: C - 0: No, 1: Yes
3 972 3 LD Writing ON/OFF: M - 0: No, 1: Yes
3 972 4 LD Writing ON/OFF: Y - 0: No, 1: Yes
PROCESS CONTROL
211Set VG: K
Sets VG in fixed potential control
mode for each color.
700 300 to 900 (V)
2 1 2 Set VG: C 700 300 to 900 (V)
2 1 3 Set VG: M 700 300 to 900 (V)
2 1 4 Set VG: Y 700 300 to 900 (V)
2 201 1 Set VB: K
Sets VB (development bias) in
fixed potential control mode for
each color
500 200 to 800 (V)
Do not change the factory
settings.
2 201 2 Set VB: C 500 200 to 800 (V)
2 201 3 Set VB: M 500 200 to 800 (V)
2 201 4 Set VB: Y 500 200 to 800 (V)
2 201 5 VB at Rev. Rotation: K
Sets VB for each color during
revolver rotation.
120 0 to 500 (V)
Do not change the factory
settings.
2 201 6 VB at Rev. Rotation: C 120 0 to 500 (V)
2 201 7 VB at Rev. Rotation: M 120 0 to 500 (V)
2 201 8 VB at Rev. Rotation: Y 120 0 to 500 (V)
AROUND THE DRUM/BELT UNITS
PROCESS CONTROL
SM APPENDIX 11-30 A166/A187/A189
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA