3.4 SWITCHES
Scanner IPU
Simbol No. Function Note
SW1
(All switches should
be always OFF.)
SW1-1
Scanner free run in
normal speed
ON: Perform
SW1-2
Scanner Motor ON: Motor off,
OFF: Motor on
SW1-3
Exposure Lamp ON: Lamp off,
OFF: Lamp on
SW1-4
OpticsCooling Fan
1 and 2
ON: Motor off,
OFF: Motor on
SW1-5
Optics Exhaust Fan ON: Motor off,
OFF: Motor on
SW1-6
Scanner Board
Cooling Fan
ON: Motor off,
OFF: Motor on
[SW1-6] - [SW1-7]
Image I/O signal
selection
OFF-OFF: YMCK
signal output
ON-OFF: Image
signal output from
RGB connector
(Factory use only)
OFF-ON: Image
signal input through
the RGB
connector(Factory use
only)
ON-ON: YMCK signal
output
SW1-8
Scanner free run in
half-speed
ON: Perform
SCU
Simbol Description
SW1 Reset switch
SW3 Do not change the default (Default: OFF)
SW4 ID number for CSS/RDS (Japan Only)
TB1 Loop for CSS/RDS (Japan Only)
Service
Tables
TP/FUSE/LED/SW
SM 4-35 A166/A187/A189