3. TROUBLESHOOTING FOR COUNTERS
Check the backup counter values
SP7-3-1 Bk counter
SP7-3-2 Full Color counter
value B
Compare the main and
backup counter
referring to the previous servicing
counter.
Judge which counter
is defective.
Enter SP mode
SP7-914-3 :
Write the main counter value to the backup counter
to check the main counter value.
This is because you can not access the main
counter value using the counter key on the operation
panel directly.
Main SW OFF/ON
If the backup counter values have a problem, other
RAM data also might have problems.
RAM Clear
(See Section 6.12.2)
Is SC901 still displayed?
SC901
Main SW OFF
Replace the main counter
Main SW ON
(SC901 will be displayed)
Write the main counter value to the backup
counter to be consistent with the main counter.
SP7-914-3 :
Check the backup counter
SP7-3-1 Bk : 9998000
SP7-3-2 Full Color : 9999000
Main SW OFF/ON
END
Replace the memory
board
Write the main counter value to the backup
counter to be consistent with the main counter.
SP7-914-3
Check the backup counter
SP7-3-1 Bk counter
SP7-3-2 Full Color counter
Main SW OFF/ON
value A
Judge again
Inconsistent main and backup
counters
Main Counter
P/N : A1669099
Counter value :
1: 9998000
2: 9999000
Defective main counter
value:
value A is correct.
Defective backup counter
value:
value B is correct.
Defective memory board
Defective main
counter
Check the backup counter values, which now equal
the main counter values.
SP7-3-1 Bk counter
SP7-3-2 Full Color counter
END
Yes
No
Trouble-
shooting
TROUBLESHOOTING FOR COUNTERS
SM 6-37 A166/A187/A189