3.2 FUSE CONDITIONS
AC Drive/DC Power Supply Board
FUSE
Rating
Function Condition
220/240 V 115 V
FU101 250 V, 6.3 A 125 V, 15 A AC IN LINE If defective, no response.
*FU102 250 V, 1.6 A 250 V, 3.15 A AC STANBY
If defective, anti-condensation
heater does not work.
FU200 250 V, 6.3 A 125 V, 8 A
Main Control Board
FUSE Rating Function Note
F201 250V, 1A
To prevent the toner supply
motor from drawing exessive
current.
If defective, power will not be
supplied, the machine will then
enter a toner end condition.
3.3 LED CONDITIONS
No. Function Note
Scanner IPU
LED1
After the main switch is on, this
LED is always blinking.
When LED1 is off and LED5 is on,
a SCSI IC error might have
occured.
LED5
When the scanner IPU board is
connected with SCSI bus, this LED
is on.
Main Control Baord
LED201
Lamp ON: Indicates the CPU in an
abnormal condition.
Instruction error, Bus error, or
Address error
LED202
Blinking: Indicates active After the main switch is on and
CPU starts, this LED is always
blinking.
LED203 Lamp On: FGATE is ON.
* Fuse is a ceramic type ("canned ") and is soldered on the Power Supply
Pcb.