49. Place the drum unit on a clean sheet of paper or floor mat, as shown above.
Turn it over in the direction shown. Then remove the two screws [A] and
open the drum unit, as shown.
NOTE: 1) Use a clean sheet of paper or floor mat when placing the
drum unit on the floor. This stops the floor getting dirty.
2) Turn over the drum unit in the direction shown above. If turned in
the opposite direction, used toner from the drum may spill out.
50. Remove the drum protective sheet [B] and the cardboard cleaning blade release
wedge [C]. Apply setting powder to the drum’s surface if necessary, then
reassemble the drum unit by reversing the previous step. Do not apply an
excessive amount of setting powder to the drum when "dusting" the drum’s
surface.
51. Reinstall the drum unit (3 connectors).
NOTE: 1) When reinstalling the drum unit, ensure there is no gap at [D]
(the ends should be flush). If there is a gap, turn the drum
counterclockwise from the edge of the drum and reinsert the
drum in the machine. This ensures that the gears mesh correctly.
2) Ensure that all 3 connectors are securely connected before
proceeding with the installation.
3) Do not hold the drum at the hole at the rear. If the grounding
plate in this hole is bent, the drum will not contact the drum
shaft correctly.
[A]
[B]
[C]
Rev. 1/97
[D]
COPIER INSTALLATION
A166/A187/A189 3-24 SM
CÓPIA NÃO CONTROLADA