Savin 4027 Service Manual Page 239

  • Download
  • Add to my manuals
  • Print
  • Page
    / 708
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 238
1.13 TONER SCATTERING
- Problem -
Toner scatters from the development unit.
- Possible Causes -
1. The toner density is too high.
2. The inlet seal on the development unit is out of position.
3. The developer has deteriorated.
- Action -
Is the toner density too high?
No Yes
See section 1.11 "Toner Density Too High".
Is the inlet seal deformed?
No Yes
Replace the inlet seal plate.
Replace the developer.
A156/A160/A162 6-20 FSM