3.2 DEVELOPER REPLACEMENT
1. Take out the development unit and place it on a clean sheet. (See
Development Unit Removal.)
2. Disconnect the connector [A] and separate the toner supply unit [B] from the
development unit (2 screws).
3. Turn over the development unit and empty all the developer [C] onto the
sheet [D]. Make sure that no developer remains on the development roller or
in the unit.
NOTE:
Dispose of the used developer in accordance with local regulations.
[I]
[H]
[A]
[B]
[C]
[D]
[E]
[G]
[F]