4.7 QUENCHING LAMP REPLACEMENT
1. Remove the following parts:
Development unit
Drum unit
2. Lower the transfer belt unit and place a sheet of paper [A] over the transfer
belt.
NOTE:
This step prevents the quenching lamp from damaging the transfer
belt if it falls.
3. Disconnect the connector [B] (CN108) from the main board.
4. Remove the screw [C] and push the quenching lamp [D] halfway in from the
front until its front end does not fall down.
5. Remove the quenching lamp [D] from the back of the copier.
[A]
[C]
[B]
[D]