Savin 4027 Service Manual Page 215

  • Download
  • Add to my manuals
  • Print
  • Page
    / 708
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 214
11.3 DC POWER SUPPLY BOARD REPLACEMENT
NOTE:
Check the fuses (FU301, FU302, FU303, and FU304) on the board
before determining that the dc power supply board is defective.
1. Turn off the main switch and unplug the machine.
2. Remove the rear cover.
3. Replace the dc power supply board [A] (7 screws and all connectors).
NOTE:
6 screws for 115V machines.
[A]
A156/A160/A162 5-68 FSM
CÓPIA NÃO CONTROLADA