What To Do If Something Goes Wrong
180
4
When The Master End Indicator (
C
) Lights
The Master End indicator (
C
) lights when it is time to replace the master roll or
when you need to set the master roll.
R
CAUTION:
A Pull out the master feed unit until it stops.
B Open the master guide.
C Open the master feed unit cover (1).
D Remove the used master roll (2).
Note
When the Master End indicator is lit, it is necessary to replace the master
roll even if some master remains on the old roll.
E The new master roll must be positioned as shown in the illustration (1).
F Close the master feed unit cover (2).
This machine has been tested for safety using this supplier's
parts and consumables. We recommend you only use these
specified supplies.